Author |
Message |
|
Post subject: problem s prenosovou rychlostou
Posted: 24.02.2016 - 07:03 #110691
|
|
Basic
Joined: Jún 12, 2014
Posts: 11
|
|
Zdravim,
vedeli by ste mi poradit, kde by mohol byt problem?
Mam nasledovnu konfiguraciu: gateway mikrotik x86 (A) ___ router RB850G (B) ___ AP powerbeam AC --- CPE powerbeam AC ___ router RB750G2 Hex (C) ako switch. Na gateway je NAT.
Ked pustim btest z A do C, tak nameram download cca 99 Mbits. Ked pustim btest zo serveru mimo mojej siete do A alebo do B, tak nameram download tiez cca 99 Mbits. Ale ked pustim btest so serveru vonku do C, tak nameram download len max polovicu, do 45 Mbits. Vsetky testy su s 20 spojeniami. Vsetky eth porty na mikrotikoch mam zlinkovane na 100 Mbit FD. Interface queue mam pfifo s queue size 5000 paketov. Kde moze byt problem?
Dakujem za kazdu radu. |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 24.02.2016 - 19:01 #110698
|
|
Basic
Joined: Júl 17, 2003
Posts: 73
Location: Vychod Slovenska
|
|
UBNT robia test na udp paketoch , mikrotik mas na tcpip potvrdzovanych , tam je pes zakopany... ubnt nedava realne testy pri tcpip zatazi |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 25.02.2016 - 07:13 #110703
|
|
Basic
Joined: Jún 12, 2014
Posts: 11
|
|
Diky za odpoved, ale nerobim testy priamo medzi UBNT zariadeniami. Robim testy vzdy z mikrotiku na mikrotik. UBNT je len bridge. |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 26.02.2016 - 19:51 #110713
|
|
Majster
Joined: Máj 12, 2004
Posts: 4579
Location: Bratislava
|
|
skus zapnut flow control a daj vediet... |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 27.02.2016 - 06:22 #110715
|
|
Ucen
Joined: Apr 18, 2008
Posts: 561
Location: Toropark
|
|
nieco podobne sme riesili asi pred troma rokmi... bude to tym flow controlom ako pise aj chalan... |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 29.02.2016 - 10:02 #110719
|
|
Ucen
Joined: Júl 15, 2011
Posts: 769
|
|
 |
Last edited by pedro4444 on 01.03.2016 - 08:28; edited 1 time in total
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 29.02.2016 - 10:42 #110722
|
|
Majster
Joined: Máj 12, 2004
Posts: 4579
Location: Bratislava
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 01.03.2016 - 09:58 #110733
|
|
Basic
Joined: Jún 12, 2014
Posts: 11
|
|
Parada, diky za radu!
Zapol som najprv flow control medzi A a B, ako aj medzi B a Powerbeamom, ale nezlepsilo sa to. Tak som prepol link medzi A a B zo 100Mbit na 1Gbit a az potom zacala ficat cela trasa az do tych 95 Mbit. Nechapem, v com bol to moze byt, ale aspon to uz ide. |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 18.10.2016 - 20:33 #111806
|
|
Basic
Joined: Jan 23, 2009
Posts: 176
|
|
Neviete nahodou ci sa uz da na nanobeam/powerbeamoch nejako cez konzolu zapnut flow control ? |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 18.10.2016 - 21:28 #111808
|
|
Basic
Joined: Aug 14, 2011
Posts: 209
|
|
flow control som zapinal/vypinal na mikrotiku, ak sa robilo napr. mangle alebo nat tak muselo byt flow control zapnute inak nefungovalo...co to vlastne je?
ja som to vzdy vypinal na mikrotiku ked to robilo iba routing. vytazenost cpu vtedy vyrazne klesla |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 21.10.2016 - 08:47 #111818
|
|
Basic
Joined: Jan 23, 2009
Posts: 176
|
|
xtome2 wrote: ›flow control som zapinal/vypinal na mikrotiku, ak sa robilo napr. mangle alebo nat tak muselo byt flow control zapnute inak nefungovalo...co to vlastne je?
ja som to vzdy vypinal na mikrotiku ked to robilo iba routing. vytazenost cpu vtedy vyrazne klesla
Ak stroj nestiha spracuvat data poziada protistranu o "spomalenie" . Ide mi o riesenie problemu pri prechode siete 1G na 100m resp bezdrat , kde sa potom deju podivne anomalie , polovicna rychlost u klienta , alebo este nizzsia ... |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 21.10.2016 - 15:34 #111819
|
|
Basic
Joined: Aug 14, 2011
Posts: 209
|
|
kemper wrote: › xtome2 wrote: ›flow control som zapinal/vypinal na mikrotiku, ak sa robilo napr. mangle alebo nat tak muselo byt flow control zapnute inak nefungovalo...co to vlastne je?
ja som to vzdy vypinal na mikrotiku ked to robilo iba routing. vytazenost cpu vtedy vyrazne klesla
Ak stroj nestiha spracuvat data poziada protistranu o "spomalenie" . Ide mi o riesenie problemu pri prechode siete 1G na 100m resp bezdrat , kde sa potom deju podivne anomalie , polovicna rychlost u klienta , alebo este nizzsia ...
jaaaj jasne, ja som si to pomylil s connection tracking |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 21.10.2016 - 15:49 #111820
|
|
Basic
Joined: Apr 05, 2012
Posts: 22
|
|
Nenasiel som na nete nic viac o flow-control. Je treba zapnut flow na obidvoch stranach linky alebo staci na jednom stroji ? skusil som iba na jednej strane a zatial testy vysli dobre. Dik za dalsie info. |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 22.10.2016 - 09:50 #111821
|
|
Basic
Joined: Jan 23, 2009
Posts: 176
|
|
user wrote: ›Nenasiel som na nete nic viac o flow-control. Je treba zapnut flow na obidvoch stranach linky alebo staci na jednom stroji ? skusil som iba na jednej strane a zatial testy vysli dobre. Dik za dalsie info.
Treba zapnut na oboch stranach . Ak ma tuto funkciu nemanazovatelny switch , tak ide flowcontrol nonstop ... Problem je vtom ze zariadenia UBNT nemaju flowcontrol ... okrem af a AC . |
|
|
|
|
 |
|
Post subject: RE: problem s prenosovou rychlostou
Posted: 23.10.2016 - 19:57 #111827
|
|
Basic
Joined: Jan 23, 2009
Posts: 176
|
|
|
|
 |
|
Powered by PNphpBB2 © 2003-2005 The PNphpBB Group Credits |